We have leakage in film-seal applications—where should we start?

First verify flange flatness and cleanliness; oil, water, or flour/salt particles compromise sealing. Then check film type (peelable/weld), the heat–time–pressure window, and plate/tool temperature uniformity. If needed, increase flange width, select a gasketed lidding film, or add a perimeter band as secondary security.

Packmaster Support Commercial